Dual-Energie Röntgenbildgebung für gezielte Radiotherapie
View on FWF Research RadarKeywords
Research Disciplines
The DEXTER consortium, consisting of the radART (Paracelsus Medical University, Salzburg, Austria) and CREATIS (Université Lyon 1, Lyon, France) institutes, aims at exploiting the capabilities of PAIR, a newly developed integrated Patient Alignment and x-ray Imaging Ring system for image guided radiotherapy (IGRT). IGRT has been a booming field of research and PAIR pushes forward the capabilities of in-room 2D and 3D imaging. Three main objectives and fields of research were determined in the DEXTER project: 1. Oblique x-ray projection images can provide large field of view (FOV) computed tomography (CT) images. Today, existing cone-beam CT (CBCT) scanners allow in plane displacement of their flat panel. PAIR on the other hand allows independent rotation of the flat panel and x ray source; it can thus reach much larger FOVs. PAIR is, to our knowledge, the only scanner in the field of IGRT enabling this geometry. However, new reconstruction algorithms are required and will be investigated in DEXTER, therefore increasing the maximal size of 3D CBCT FOV. 2. Future x-ray scanners will exploit multiple x-ray energies. This is an important research field in Lyon because a photon counting spectral scanner will soon be installed in the context of France Life Imaging (FLI). One perspective is the better characterization of tissue composition which is essential in hadron therapy for predicting the range of the ion beam. With PAIR, we have the unique opportunity to investigate the capabilities of dual- energy in the treatment room. DEXTER will provide guidelines on the achievable accuracy of ion range prediction which will be validated on real experiments, the current knowledge being essentially restricted to Monte Carlo simulations. Successful improvement will translate in smaller treatment margins for hadron therapy centers equipped with PAIR units. 3. Finally, new opportunities for 2D/3D intrafraction tumor localization will be explored based on PAIR`s capabilities, namely, multi-energy radiographs and maximal collimation of the x-ray beam. There are two objectives, solving target occlusion difficulties while minimizing the imaging dose. Improving intrafractional position verification and online treatment guidance directly impacts the treatment margins accounting for uncertainties in the target position. If one can also minimize the imaging dose, continuous tracking during treatment delivery might be feasible. The end results are twofold. First, the new knowledge will be disseminated via conventional means, i.e., conferences in the medical imaging field and in the radiotherapy domain as well as corresponding journals. Second, the algorithms, developments and representative data sets will be open source via collaborative platforms that have been initiated by the two partners, i.e., the Reconstrution Toolkit (RTK) for CBCT reconstruction and Reg23 in Plastimatch for 2D/3D registration.
This project has no linked research outputs in the database.
No additional funding sources recorded.
Research Fields